RL5 series explosion proof repeater light is used in the helicopter landing areas of oil and chemical plants and offshore oil and gas platforms. It provides safe landing guidance for helicopter pilots and meets the requirements of CAP437.
Features:
● Conform to CAP437 8th Edition-6.8 | ● Conform to HCA -Standard Helideck Monitoring System Rev 9b |
● Automatic switching between day/night brightness | ● Blue/amber/red LED light source |
● 316L stainless steel housing | ● Complies with requirements for marine and oil and gas industrial environments |
Function description:
■ Pre-landing
Blue | steady on | "Safe landing" |
Amber | steady on | "Consider using modified operating procedures" |
Red | steady on | "Do not land" |
■ Post-landing
Blue | slow flashing | "Relative wind within limits" |
Amber | flash flash | "Imminent relative wind overrun" |
Red | flash | "Relative wind overrun" |
Technical Parameters:
■ Certification
Certification: | China Ex |
Ex-mark: | Ex db eb mb IIC T4/T5/T6 Gb |
Ambient temperature: | -40℃~+60℃ |
Zone : | Zone 1, Zone 2 |
■ Physical properties
Ingress protection: | IP66 |
Light material: | Housing material: 316L stainless steel Light: Tempered glass |
Mounting parts material: | 316L stainless steel |
Light color: | Silver gray color |
*Cable entry: | 4×M25/M20×1.5 |
Weight | ≤35kg |
■ Electrical properties
Light power: | Standard Helideck Monitoring System Rev 9b - 9.3 |
Color: | ICAO Annex 14 Vol.1 Appendix 1 Blue/Amber/Red,Based on platform motion and wind conditions |
Light source: | LED |
Lifespan : | >80,000 hours |
Operating mode: | Please refer to the function description for details |
Rated power: | ≤70W |
Power supply: | Please refer to the ordering information for details |
Communication *: | RS485/TCP-IP * |
* Cable gland and plug are optional as per user's needs * Communication is an optional accessory provided as per user's needs |
Ordering Information:
Example: RL5-220Y= 220Vac power supply ,exist communication
Installation: